Inorganic phosphate solvent resistant coating

The coating is composed of inorganic phosphate, ultrafine zinc powder (aluminum powder), pigment filler, and the like, using water as a dispersion medium.
Retail price
0.0
Market price
0.0
Number of views:
1008
Product serial number
Quantity
-
+
Stock:
0
1
产品描述

555

product manual
The coating is composed of inorganic phosphate, ultrafine zinc powder (aluminum powder), pigment filler, and the like, using water as a dispersion medium.
The product is a two-component package, component A is liquid and component B is powder.
Product Usage
The coating is widely used for anti-corrosion coating on all steel products. It can be used as shop primer and heavy anti-corrosion primer coating. It is more suitable for high-temperature partial coating and strong solvent tank inner wall coating. Such as the inner and outer walls of the hot blast stove, smoke windows, drying tunnels. Hot exhaust pipe, blast furnace, boiler, heating furnace, etc. It can also be used as a base for heavy anti-corrosion coatings. It can be applied to the ironwork without any hindrance to the welding of the painted steel surface. The coating is particularly resistant to seawater, oil, ketone, benzene, ether and other strong solvents. It can be used in combination with various paints, complement each other, and has a long-term anti-corrosion effect. It can also be used as a conductive primer for metal oil tanks. It can be used in metallurgy, chemical industry, electric power, machinery, shipbuilding, aircraft, roof truss, oil field pipeline, coal mine derrick, etc. The coating is environmentally friendly and non-toxic.
Physical characteristics
colour

gray

Volume solids (mixed)

55±3%

Recommended film thickness

Dry film: 80μm
Wet film: 145μm

Theoretical dosage

0.413kg/㎡ @80μm

Dry(23±2℃)

≤0.5h

Hard work(23±2℃)

≤12h

Fully cured(23±2℃)

7d

Surface treatment
The surface of the steel structure is sandblasted to Sa21/2 or above, and the surface roughness reaches 30~75μm;
The surface to be painted should be kept dry and clean without debris.
Construction instructions
The mixing ratio

Component A: Component B = 2:5 (weight ratio)
Add the powder to the liquid and repeat it with a power tool.

Maturing time

5~15min(23±2℃)

Mixed use period

≤1h(23±2℃)

Thinner

WJX inorganic zinc-rich thinner

Construction method

Painting method

Brushing, roller coating (applicable)

Air spray (applicable)

Airless spray (recommended)

Dilution rate

/

/

/

Airless spraying: ejection pressure: 15~17MPa
Nozzle diameter: 0.43~0.53mm
Air spray: Adjust the viscosity with the matching diluent: 25-30 S (coating -4/23 ± 2℃)
Recoat interval
Construction temperature

5℃

20℃

30℃

Minimum recoating time

48h

24h

12h

Maximum recoating time

Unlimited

Unlimited

Unlimited

* When the paint film is exposed to excessive outdoor time, zinc salt will be formed, which will adversely affect the adhesion of the heavy coating. Therefore, the surface of the paint film must be subjected to brushing, sand sweeping or high-pressure fresh water rinsing, and sufficient time can be maintained during recoating. Interlayer adhesion.
Tool cleaning All tools must be cleaned with WJX inorganic zinc-rich thinner.
 
Safety
Use this product with care. Please refer to the MSDS of this product before starting work.
Please pay attention to the safety precautions on the packaging label before and during use. In addition, the safety regulations prescribed by the relevant national or local government should also be observed.
Personal protection includes, but is not limited to, lung, eye and skin protection. If swallowed or otherwise in contact with this product, seek medical attention immediately. Precautions must be taken to prevent fire, explosion and environmental protection.
Precautions
The construction site shall be protected from open flames and may only be constructed in a well ventilated condition. Strong ventilation is required in applications where it is confined or where air is not circulating.
Air humidity: The ambient humidity is less than 50%. Construction is not recommended.
Ambient temperature: When the ambient temperature is continuously below 5 °C or above 45 °C, construction is not recommended.
Surface temperature of the substrate: The surface temperature of the steel must be higher than the dew point by 3 °C during construction; however, if the surface temperature is too high, the film defects will be caused. Therefore, when the surface temperature of the substrate is higher than 50 °C, the construction conditions should be adjusted and the construction at noon will be carried out. Move to morning and evening.
Other aspects: When painting, it is necessary to prevent the surrounding environment from causing pollution to the paint film, such as: sandblasting, paint fog lamps. Avoid construction in the case of rain, snow, fog, sandstorms, and stop construction in areas with strong winds or high pollution. Excessive ventilation will cause the coating to dry too quickly and the paintability of the coating will deteriorate, and a large amount of pollutants ( Such as sand, salt particles, corrosion deposits) will cause the film properties to deteriorate, and the loss will increase.
After the two components are mixed, they are filtered using an 80-100 mesh filter bag and used. Stir with a dispersing machine and continue to stir during use to prevent precipitation of zinc powder.
For best performance, the temperature of the film should be kept above 10 °C during film formation, and the humidity should be kept above 65%. If the humidity is lower than required, spray air into the air with air spray gun or other methods after the construction is completed. In order to increase the humidity, it is forbidden to directly spray water on the surface of the coating to avoid film defects.
Oil-based resin paints, alkyd resin paints and other alkali-resistant paints cannot be directly coated on inorganic zinc-rich primers. The zinc salt formed on the surface of the paint film must be completely removed when the coating time is long.
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Our professional production and development of high performance heavy anti-corrosion coating

Widely used in petrochemical, marine engineering, engineering machinery, various types of ships, steel structures, bridges, wind power facilities, containers, etc., supplemented by floor coatings, fireproof coatings, temperature-resistant coatings, interior and exterior wall coatings, etc. .

Paint

Contact us :

Home    About Us    Products    Projects    News    Qualification    Contact Us 

Jiangsu Zhongren Paint Co., Ltd.  Powered by www.300.cn   苏ICP备19024502号-2