Epoxy coal tar pitch anticorrosive coating

A two-component coating consisting of epoxy resin, phenolic coal tar pitch, rust preventive pigment, thickener and curing agent. The product has good construction performance, high spray paint film thickness, tough film, good adhesion and excellent anti-corrosion performance.
Retail price
0.0
Market price
0.0
Number of views:
1019
Product serial number
Quantity
-
+
Stock:
0
1
产品描述

环氧煤沥青防腐涂料

product manual
A two-component coating consisting of epoxy resin, phenolic coal tar pitch, rust preventive pigment, thickener and curing agent. The product has good construction performance, high spray paint film thickness, tough film, good adhesion and excellent anti-corrosion performance. It can provide long-term protection in the ocean and other harsh environments.
Product Usage
It is suitable for surface anti-corrosion of buried pipelines, steel, wood products, cement products, etc. and is used for general atmospheric anti-corrosion coating. Sluice gates, coal mine mine supports, buried, atmospheric pipelines, etc. for anti-corrosion coating.
Physical characteristics
colour

Brown, black

Volume solids

65±3%

Recommended film thickness

Dry film: 100μm
Wet film: 150μm

Theoretical dosage

0.215kg/㎡ @100μm

Dry surface (23±2℃)

≤2h

Hard work (23 ± 2℃)

≤24h

Fully cured(23±2℃)

7d

Surface treatment
The surface of the steel structure is sandblasted to Sa21/2 or above, and the surface roughness is 30~75μm; the surface to be coated should be kept dry and clean without debris.
Construction instructions
The mixing ratio

Component A: Component B = 22:3 (weight ratio)
Stir well with mechanical agitation

Maturing time

5~30min(23±2℃)

Thinner

HY epoxy thinner

Construction method

Painting method

Brushing, roller coating (applicable)

Air spray (applicable)

Airless spray (recommended)

Dilution rate

0~10%

0~10%

0~5%

Airless spraying: ejection pressure: 15~17MPa
Nozzle diameter: 0.46~0.58mm
Air spray: Adjust the viscosity with the matching diluent: 25-30 S (coating -4/23 ± 2 °C)
Recoat interval
Construction temperature

5℃

20℃

30℃

Minimum recoating time

24h

12h

8h

Maximum recoating time

Unlimited

Unlimited

Unlimited

* When the paint film is exposed for a long time outdoors or the surface is smooth, it has a bad influence on the adhesion of the heavy coating. Therefore, the surface of the paint film must be subjected to brushing, sand sweeping or high-pressure fresh water rinsing, and sufficient time can be maintained during recoating. Interlayer adhesion.
Tool cleaning
All tools must be cleaned with HY epoxy thinner
Safety
Use this product with care. Please refer to the MSDS of this product before starting work.
Please pay attention to the safety precautions on the packaging label before and during use. In addition, the safety regulations prescribed by the relevant national or local government should also be observed.
Personal protection includes, but is not limited to, lung, eye and skin protection. If swallowed or otherwise in contact with this product, seek medical attention immediately. Precautions must be taken to prevent fire, explosion and environmental protection.
Precautions
The construction site shall be protected from open flames and may only be constructed in a well ventilated condition. Strong ventilation is required in applications where it is confined or where air is not circulating.
Air humidity: When the relative humidity of the air is greater than 80%, construction is not recommended.
Ambient temperature: When the temperature is between -5 and 15 °C, it is recommended to use winter-type products. The temperature is higher than 15 °C and lower than 45 °C. It is recommended to use ordinary products, below -5 °C or above 45 °C. Construction is not recommended.
Surface temperature of the substrate: When the surface temperature of the steel is lower than the dew point temperature of 3 °C, the construction is not recommended. If the surface temperature of the steel is too high, the surface of the paint film will be defective. Therefore, when the surface temperature of the steel is higher than 50 °C, the construction conditions should be adjusted and it will be noon. The construction will be moved to the morning and evening, or the awnings will be erected or moved to the workshop.
Other aspects: There should be good ventilation during construction. When painting, it should prevent the surrounding environment from causing pollution to the paint film, such as sandblasting and paint fog lamps. Avoid construction in the case of rain, snow, fog, sandstorms, and stop construction in areas with strong winds or high pollution. Excessive ventilation will cause the coating to dry too quickly and the paintability of the coating will deteriorate, and a large amount of pollutants ( Such as sand, salt particles, corrosion deposits) will cause the film properties to deteriorate, and the loss will increase.
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Our professional production and development of high performance heavy anti-corrosion coating

Widely used in petrochemical, marine engineering, engineering machinery, various types of ships, steel structures, bridges, wind power facilities, containers, etc., supplemented by floor coatings, fireproof coatings, temperature-resistant coatings, interior and exterior wall coatings, etc. .

Paint

Contact us :

Home    About Us    Products    Projects    News    Qualification    Contact Us 

Jiangsu Zhongren Paint Co., Ltd.  Powered by www.300.cn   苏ICP备19024502号-2